Honeywell Modutrol Motor
Model Time (s) Load torque (Nm) Power supply (V)M6284 30 17 230M7284 30 17 230M7297 30 34 230M9184 30 17 230Honeywell Satronic Burner Control
Satronic combustion controllerDK0970 single stage fuel controller < 30kg/hDK0972 Dual stage fuel controller < 30kg/hDM0976 Dual stage fuel controller > 30kg/hTF830. 3 single stage fuel controller < 30kg/hTF832. 3 Dual stage fuel controller < 30kg/hTF834. 3 Dual stage fuel controller < 30kg/hMM0872 Dual stage fuel controller > 30kg/hDKG972 Dual stage, atmospheric gas controllerDMG970 Dual stage, blast gas controllerDMG971 Dual stage,...HONEYWELL SATRONIC IGNITION TRANSFORMER
Model Input Voltage (V) Output Voltage (kV) Output Current (mA) Ignition efficiency (%)ZT812 230 1x10 16 25ZT870 230 1x16 40 50ZT930 230 2x7 40 33ZT931 230 1x14 40 33Honeywell Servomotor LKS Series
Model Time (s) Load torque (Nm) Power supply (V)LKS118 5 0.6 230LKS131 5..30 0.6 230LKS160 5..30 1.5-3 230LKS170 5..30 1.4-2.8 230LKS210 5..30 1.5 230LKS310 7..30 7-15 230Honeywell UV SENSOR
Model Spectral detection ApplicationC7008A, C7009A IonizedC7015A InfraredC7027A Ultraviolet lightC7035A Ultraviolet light Detachable, function as per C7027AC7012A Ultraviolet lightC7012C Ultraviolet light Explosion proofC7012E Ultraviolet light Self-testC7012F Ultraviolet light Self-test, explosion proofC7076A Ultraviolet light Self-test, explosion proofI Beam Conveyor & Trolley
McHEAT Offers a full line of trolleys to fit every application we have many available options ranging from lightweight to heavy duty, and have trolleys and attachments suitable for any systemKromschroder Air Pressure Switch
Specifications:DG 6U-3: Adjusting range: 0.4-6 mbar DG 10U-3: Adjusting range: 1 to 10 mbar DG 50U-3: Adjusting range: 2.5 to 50 mbar DG 150U-3: Adjusting range: 30 to 150 mbar DG 500U-3: Adjusting range: 100 to 500 mbar Electrical connection via screw terminals, Connection 1/4" NPTF Item Code: DGKromschroder Burner Control Unit
Burner controller Flame detection Start time (s) MalfunctionBCU 440 Ionised 3-10 Faulty lockBCU 460 Ion or UV 3-10 Faulty lockBCU 480 Ion or UV 3-10 Faulty lock Automatic burner control unit, ignition transformer, indicators and operating controls in a space-saving metal housing which replaces the local burner control cabinet For directly ignited burners of up to 350 kW in continuous operation pursuant...KROMSCHRODER GAS FILTER
Model Connection Work pressure (bar) Connection methodGFK 15R10-4 1/2" 1 FlangeGFK 20R10-4 3/4" 1 FlangeGFK 25R10-4 1" 1 FlangeGFK 32R10-7 11/4" 1 FlangeGFK 40R10-7 11/2" 1 FlangeGFK 50R10-7 2" 1 FlangeGFK 65R10-7 DN65 1 FlangeGFK 80F10-3 DN80 1 FlangeKromschroder Gas Regulator VGBF & GDJ Series
Model Connection method CaliberWork pressure (bar) Adjustment range (mbar)VGBF 15R40-1 Thread 1/2"4 20VGBF 25R10-1 Thread 1"1 20VGBF 25R40-1 Thread 1"4 20VGBF 40R10-3 Thread 1-1/2"1 20VGBF 40F40-3 Flange DN404 20VGBF 50F10-3 Flange DN501 20VGBF 80F40-3 Flange DN804 20J78R1/0 Thread 1/2"0.1 15-23GDJ 15 Thread 1/2"4 2-55GDJ 20 Thread 3/4"4 5-160GDJ 25 Thread 1"4 5-160GDJ 40 Thread 1-1/2"4 5-160GDJ 50 Thread 2"4 5-100KROMSCHRODER Gas Valve VG 6/8/10/15 R
Model Connection Size Work Pressure (bar)VG 6R Rp 1/8 0.5VG 8R Rp 1/4 0.35VG 10R Rp 3/8 0.1VG 15R Rp 1/2 0.1Loading
No Products for load
Showing 85–96 of 155 results